Sampling, separation, and quantification of N‐acyl homoserine lactones from marine intertidal sediments

Cirri, Emilio

Nuwanthi, Samarasinghe Gunasekara Liyanage Ishari
Stock, Willem
Ueberschaar, Nico
Mangelinckx, Sven
Pohnert, Georg

Vyverman, Wim
DOI: https://doi.org/10.23689/fidgeo-4220
Cirri, Emilio; 2 Institute for Inorganic and Analytical Chemistry Friedrich Schiller University Jena Jena Germany
Nuwanthi, Samarasinghe Gunasekara Liyanage Ishari; 4 SynBioC, Department of Green Chemistry and Technology, Faculty of Bioscience Engineering Ghent University Ghent Belgium
Stock, Willem; 1 Laboratory of Protistology and Aquatic Ecology, Department of Biology Ghent University Ghent Belgium
Ueberschaar, Nico; 5 Mass Spectrometry Platform Friedrich Schiller University Jena Jena Germany
Mangelinckx, Sven; 4 SynBioC, Department of Green Chemistry and Technology, Faculty of Bioscience Engineering Ghent University Ghent Belgium
Vyverman, Wim; 1 Laboratory of Protistology and Aquatic Ecology, Department of Biology Ghent University Ghent Belgium
Abstract
N‐acyl homoserine lactones (AHLs) are molecules produced by many Gram‐negative bacteria as mediators of cell‐cell signaling in a mechanism known as quorum sensing (QS). QS is widespread in marine bacteria regulating diverse processes, such as virulence or excretion of polymers that mediate biofilm formation. Associated eukaryotes, such as microalgae, respond to these cues as well, leading to an intricate signaling network. To date, only very few studies attempted to measure AHL concentrations in phototrophic microbial communities, which are hot spots for bacteria‐bacteria as well as microalgae‐bacteria interactions. AHL quantification in environmental samples is challenging and requires a robust and reproducible sampling strategy. However, knowing about AHL concentrations opens up multiple perspectives from answering fundamental ecological questions to deriving guidelines for manipulation and control of biofilms. Here, we present a method for sampling and AHL identification and quantification from marine intertidal sediments. The use of contact cores for sediment sampling ensures reproducible sample surface area and volume at each location. Flash‐freezing of the samples with liquid nitrogen prevents enzymatic AHL degradation between sampling and extraction. After solvent extraction, samples were analyzed with an ultra‐high performance liquid chromatography‐high resolution mass spectrometry (UHPLC‐HRMS) method that allows to baseline‐separate 16 different AHLs in less than 10 min. The sensitivity of the method is sufficient for detection and quantification of AHLs in environmental samples of less than 16 cm3.